800-471-4271 323-582-0891

Direct Vent Furnaces








Attractive styling and
economical and safe
heating comfort with these
popular home furnaces!
Williams' compact, space-saving direct vent furnaces feature low-cost installation.
These models use no inside air for operation.
Heating rooms individually allows comfort in areas being used while saving fuel cost in unused areas.
For additional money-saving efficiency, install our optional blower.
Design Features
● No electricity required
● "Matchless" pilot igniter
● Easy installation - all vent material included
● All vent caps include built-in “Bird Guard”
● Long-life, ceramic coated combustion
chamber
● Heavy-duty, cast-iron burners
● Automatic temperature and safety controls
● Attractive, durable, soft-white, scratch
resistant finish blends with any décor
● Natural and propane gas models
(Conversions kits available)
● Thermostat included, may be wall-mounted
or cabinet-mounted
GREAT FOR GARAGE OR
WORKSHOP HEATING!
This model features a sealed combustion chamber that makes it an ideal choice for adding comfort to your garage, workshop or any place where heat is needed.

Direct-Vent Furnaces
Gas connection: ½" · Equipped with a wall-in or cabinet-mounted thermostat. · All models are rated for 4,500' elevation.
* Venting shipped with furnace for up to 9" wall thickness, 24" wall thickness available with use of extension accessories.
Features
800-471-4271 or 323-582-0891
For clean, comfortable heat when and where you want it. The gas flame is completely sealed inside, away from all contact with room air. Air necessary for combustion is drawn into the chamber from outside through direct wall vent, and all combustion products are vented directly to the outside. Only clean, gentle heat, in continuous circulation, is delivered into the room. Windows and doors can stay closed because no room air is used for combustion.
Accessories
High-Capacity Blower
Blower is easily added to the furnace.
Comes with a fully automatic fan switch.
115V power supply required.
Model 2302 for 22,000 and 30,000 Btu/hr.
Model 2303 for 14,000 Btu/hr
Shipping weight 6 lbs.
Vent-Cap Guard
Protects pedestrian traffic from heat of vent cap. Model 9308, Shipping weight 3 lbs.
Vent-Cap Guard
Insulated, galvanized sheet for all direct-vent units. Model 4318 Shipping weight 9 lbs. (Oversized)
Vent Extensions
To meet your installation needs, all models accommodate optional through-the-wall vent, which may extend up to a 24" maximum.
Model
Length
Application
Shipping Weight
9301
9302
9303
9304
15"
24"
24"
15"
22036 & 30036 Series
22036 Series
14036 & 30036 Series
14036 Series
7 lbs.
10 lbs.
10 lbs.
7 lbs
Face Panels
Model
Application
Shipping Weight
4309
4313
14036 Series
22036 & 30036 Series
16 lbs.
29 lbs.
Thin-Wall Collar Kit
For wall thicknesses from 1" to 5". Installs with vent kit. Model 9307, shipping weight 4 lbs.
Conversion Kits
Btu Size
Natural to
Propane
Propane to
Natural
14000
22000
30000
8925
8926
8927
8928
8929
8930

High-Altitude Models
Important
· Read owner's manual before using/installing.
· Photographs are representative.
· Check local codes and ordinances for permitted uses.
· Consult installation manual for clearances prior to
installation.
· We reserve to right to amend product specifications without
notice.
· Installation and servicing recommended by a qualified
service person.
· Venting must comply with the installation manual.
· New York approval MEA197-82E Vol 111 on direct-vent
models only.
250 West Laurel Street · Colton, California 92324 USA
· Massachusetts approval G3-0305-171 (909) 825-0993 · Fax:
(909) 370-0581 or (909) 824-8009
· Please read the warranty for any limitations for disclaimers.
Consumer Line: (888) 256-6465
· Combustion chamber carries a ten-year limited warranty. All
other parts carry a one-year limited warranty.
"Matchless" Pilot Igniter
All models include a "matchless" pilot igniter and a glass observation door. Assures convenient pilot lighting without matches.
Automatic Thermostat - Included with all Models
(No Electricity Required)
Equipped with a self-generating, millivolt thermostat that may be wall-mounted or cabinet-mounted.
Contemporary Finish
Light, soft-white powder-coat, scratch-resistant finish to blend with any décor.
"Bird Guard"
All vent caps include built-in "Bird Guard."

Dimensions and Clearances
● 2" from intersecting wall · 18" from top of
appliance to ceiling or other obstruction for
14,000 Btu/hr models
● 24" from top of appliance to ceiling or
other obstruction for 22,000 and 30,000
Btu/hr models

250 West Laurel Street
Colton, California 92324 USA
Homeowner Assistance: (909) 426-0978
www.e-wfc.com

Whiting Mead, Inc. Since 1898
Payment Plans Available OAC
800-471-4271 or 323-582-0891
Fax: 323-587-1379
____
Features
22,000 and 30,000 Btu/hr
14,000 Btu/hr
14,000 Btu/hr

Model Number
Btu/hr
Btu/hr
Efficiency Percentage
Dimensions
Maximum Wall Thickness*
Type of Control
Shipping Weight (lbs.)
Natural
Propane
Input Rating
Output Rating
Thermal
AFUE
Width
Depth
Height
1403622
2203622
3003622
1403621
2203621
3003621
14,000
22,000
30,000
10,039
16,462
21,849
76
75
73
63
67
66
18"
32⅛"
32⅛"
7⅛"
10¼"
10¼"
26¾"
28"
28"
24"
24"
24"
Millivolt Wall
Millivolt Wall
Millivolt Wall
56
98
100