800-471-4271      323-582-0891

Whiting Mead, Inc.  Since 1898

VisaMastercard

800-471-4271 or 323-582-0891
Fax: 323-587-1379      E-Mail

Payment Plans Available OAC
GREAT FOR GARAGE OR
WORKSHOP HEATING!
This model features a sealed
combustion chamber that makes it
an ideal choice for adding comfort to
your garage, workshop or any place
where heat is needed.
  • No electricity required
  • "Matchless" pilot igniter
  • Easy installation - all
    vent material included
  • All vent caps include
    built-in “Bird Guard”
  • Long-life, ceramic coated
    combustion chamber
  • Heavy-duty, cast-iron
    burners
  • Automatic temperature
    and safety controls
Design Features

Attractive styling and
economical and safe
heating comfort with these
popular home furnaces!

Williams' compact, space-saving directvent furnaces feature low-cost installation.
These models use no inside air for
operation.
Heating rooms individually allows comfort
in areas being used while saving fuel cost
in unused areas.
For additional money-saving efficiency,
install our optional blower.

House Garage HeaterLiving Room Wall Air Conditioner

22,000 and 30,000 Btu/hr

14,000 Btu/hr
No Electricity Bathroom Air Conditioning System
14,000 Btu/hr
  • Attractive, durable, soft-white, scratch-resistant finish
    blends with any décor
  • Natural and propane gas models (Conversions kits
    available)
  • Thermostat included, may be wall-mounted or
    cabinet-mounted

   Direct-Vent Furnaces

Model Number Btu/hr Btu/hr Efficiency Percentage Dimensions Maximum Wall Thickness* Type of Control Shipping Weight (lbs.)
Natural Propane Input Rating Output Rating Thermal AFUE Width Depth Height

1403622

1403621

14,000

10,039

76

63

18"

7⅛"

26¾"

24"

Millivolt Wall

56

2203622

2203621

22,000

16,462

75

67

32⅛"

10¼"

28"

24"

Millivolt Wall

98

3003622

3003621

30,000

21,849

73

66

32⅛"

10¼"

28"

24"

Millivolt Wall

100

Gas connection: ½" · Equipped with a wall-in or cabinet-mounted thermostat. · All models are rated for 4,500' elevation.
* Venting shipped with furnace for up to 9" wall thickness, 24" wall thickness available with use of extension accessories.

Features
Air Circulation Pattern
Accessories

For clean, comfortable heat when and where you want it. The gas flame is completely sealed inside, away from all contact with room air. Air necessary for combustion is drawn into the chamber from outside through direct wall vent, and all combustion products are vented directly to the outside. Only clean, gentle heat, in continuous circulation, is delivered into the room. Windows and doors can stay closed because no room air is used for combustion.

Features
High-Capacity Blower
Blower is easily added to the furnace.
Comes with a fully automatic fan switch.
115V power supply required.
Model 2302 for 22,000 and 30,000 Btu/hr.
Model 2303 for 14,000 Btu/hr
Shipping weight 6 lbs.
Vent-Cap Guard
Protects pedestrian traffic from heat of vent cap. Model 9308, Shipping weight 3 lbs.
Vent Shield Deflection
Insulated, galvanized sheet for all direct-vent units. Model 4318 Shipping weight 9 lbs. (Oversized)
Vent Extensions
To meet your installation needs, all models accommodate optional through-the-wall vent, which may extend up to a 24" maximum.

Model
 
9301

9302
9303
9304

Length

15"
24"

24"
15"

Application
 
22036 & 30036 Series
22036 Series
14036 & 30036 Series
14036 Series

Shipping Weight
 
7 lbs.
10 lbs.
10 lbs.
7 lbs.

Face Panels

Model
 
4309
4313

Application
 
14036 Series
22036 & 30036 Series

Shipping Weight
 
16 lbs.
29 lbs.

Thin-Wall Collar Kit
For wall thicknesses from 1" to 5". Installs with vent kit. Model 9307, shipping weight 4 lbs.
Conversion Kits

Btu Size
 
14000
22000
30000

Natural to
Propane
 
8925
8926
8927

Propane to
Natural

 
8928
8929
8930

High-Altitude Models

· Read owner's manual before using/installing.
· Photographs are representative.
· Check local codes and ordinances for permitted uses.
· Consult installation manual for clearances prior to installation.
· We reserve to right to amend product specifications without notice.
· Installation and servicing recommended by a qualified service person.
· Venting must comply with the installation manual.
· New York approval MEA197-82E Vol 111 on direct-vent models only.
250 West Laurel Street · Colton, California 92324 USA
· Massachusetts approval G3-0305-171
(909) 825-0993 · Fax: (909) 370-0581 or (909) 824-8009
· Please read the warranty for any limitations for disclaimers.
Consumer Line: (888) 256-6465
· Combustion chamber carries a ten-year limited warranty. All other parts carry a one-year limited warranty.

Important
"Matchless" Pilot Igniter
All models include a "matchless" pilot igniter and a glass observation door. Assures convenient pilot lighting without matches.
Automatic Thermostat - Included with all Models
(No Electricity Required)
Equipped with a self-generating, millivolt thermostat that may be wall-mounted or cabinet-mounted.
Contemporary Finish
Light, soft-white powder-coat, scratch-resistant finish to blend with any décor.
"Bird Guard"
All vent caps include built-in "Bird Guard."
Dimensions and Clearances
  • 2" from intersecting wall · 18" from top of appliance to ceiling or other obstruction for 14,000 Btu/hr models
  • 24" from top of appliance to ceiling or other obstruction for 22,000 and 30,000 Btu/hr models
250 West Laurel Street
Colton, California 92324 USA

Homeowner Assistance: (909) 426-0978 www.e-wfc.com